Part Number Hot Search : 
SC450 6KE40 X25F128S BC847B C6045A SC450 D1750 EMH11
Product Description
Full Text Search
 

To Download B59635T1120A062 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 PTC thermistors for overcurrent protection in telecom applications
Telecom Pair Protector (TPP), SMD
Series/Type: Date: November 2009
(c) EPCOS AG 2009. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.
Overcurrent protection for telecom Telecom pair protector (TPP), SMD
Applications Overcurrent protection for telecom applications Suitable for line card applications e.g. POTS, access networks, customer premises equipment (CPE) or integrated voice data (IVD) Features Two resistance-matched PTCs in a plastic housing Compliant with ITU-T standards basic-level lightning surges (10/700 s) basic-level power induction (600 V, 1 A, 0.2 s) power contact criteria A/B (230 V, 15 min.) Compliant with GR1089 AC power contact 120 V, 25 A, 15 min. Suitable for continuous connection to mains voltages of 110/230 V AC in tripped (high-ohmic) condition Housing material to UL94-V0 UL approval to UL 1434 (file number E69802) for RR 35 Tight resistance matching maintained after switching Negligible resistance drift after reflow soldering or switching Marked with manufacturer's logo, type designation and date code RoHS-compatible Options Alternative tolerances and resistances on request
Internal circuit
Delivery mode T15** and T16**: Blister tape, 330-mm reel with 16-mm tape, taping to IEC 60286-3 T17** and T18**: Blister tape, 380-mm reel with 24-mm tape, taping to IEC 60286-3 General technical data Max. operating voltage Operating temperature range Operating temperature range Insulating test voltage between PTC1 and PTC2 Resistance matching in one housing Resistance matching in one housing Resistance matching in one housing Vmax Top Top Vins R2 R1 R2 R1 R2 R1 245 20/+125 0/+70 >3 < 0.5 < 1.0 < 2.0 V AC C C kV
(V = 0) (V = 230 V) for RR 4.75 for RR 50 for RR = 75
Please read Cautions and warnings and Important notes at the end of this document.
Page 2 of 13
Overcurrent protection for telecom Telecom pair protector (TPP), SMD
Electrical specifications and ordering codes Type RR RR % IR IR IS ISmax Ordering code @ 25 C @ 70 C @ 25 C @ 230 V AC mA mA mA A 110 90 180 130 110 90 130 110 90 160 180 130 110 90 70 70 60 120 85 70 60 85 70 60 70 120 85 70 60 40 230 190 360 260 230 190 260 230 190 370 360 260 230 190 150 2.5 2.5 1.0 2.8 4.6 2.5 2.8 4.6 2.5 1.0 1.0 2.8 4.6 2.5 2.5 B59535T1120A262 B59550T1120A262 B59510T1120A062 B59525T1120A062 B59635T1120A062 B59650T1120A062 B59725T1120A062 B59735T1120A062 B59750T1120A062 B59805T1080A062 B59810T1120A062 B59825T1120A062 B59835T1120A062 B59850T1120A062 B59875T1120A062
Component height 7.5 mm T1535 35 +15/ 20 T1550 50 15 Component height 8.5 mm T1510 10 20 T1525 25 20 Component height 9.9 mm T1635 35 +15/ 20 T1650 50 15 Component height 10.5 T1725 25 20 T1735 35 +15/ 20 T1750 50 15 Component height 11.5 T1805 4.75 +15/ 20 T1810 10 20 T1825 25 20 T1835 35 +15/ 20 T1850 50 15 T1875 75 20
Please read Cautions and warnings and Important notes at the end of this document.
Page 3 of 13
Overcurrent protection for telecom Telecom pair protector (TPP), SMD
Switching times and ordering codes Type tS (typ.) @ ISmax, 230 V AC s tS (typ.) @ 1 A, 230 V AC s tS (typ.) @ 500 mA, 230 V AC s 1.6 1.1 16 6 3.4 2.4 4 3.4 2.4 20 19.0 6.5 4.5 3.1 2.6 Ordering code
Component height 7.5 mm T1535 0.07 0.4 T1550 0.05 0.3 Component height 8.5 mm T1510 3.6 3.6 T1525 0.2 1.4 Component height 9.9 mm T1635 0.04 0.8 T1650 0.1 0.6 Component height 10.5 T1725 0.3 1.1 T1735 0.04 0.8 T1750 0.1 0.6 Component height 11.5 T1805 4 4 T1810 3.8 3.8 T1825 0.2 1.5 T1835 0.06 1.1 T1850 0.13 0.8 T1875 0.12 0.7
B59535T1120A262 B59550T1120A262 B59510T1120A062 B59525T1120A062 B59635T1120A062 B59650T1120A062 B59725T1120A062 B59735T1120A062 B59750T1120A062 B59805T1080A062 B59810T1120A062 B59825T1120A062 B59835T1120A062 B59850T1120A062 B59875T1120A062
Please read Cautions and warnings and Important notes at the end of this document.
Page 4 of 13
Overcurrent protection for telecom Telecom pair protector (TPP), SMD
Internal circuit
Dimensional drawings in mm For type T1510 and T1525 Solder pad
For type T1535 and T1550
Solder pad
Please read Cautions and warnings and Important notes at the end of this document.
Page 5 of 13
Overcurrent protection for telecom Telecom pair protector (TPP), SMD
Dimensional drawings in mm For type T1635 and T1650 Solder pad
For type T1725, T1735, T1750
Solder pad
For type T1805 ... T1875
Solder pad
Please read Cautions and warnings and Important notes at the end of this document.
Page 6 of 13
Overcurrent protection for telecom Telecom pair protector (TPP), SMD
Reliability data Test Electrical endurance, cycling Electrical endurance, constant Damp heat Standard IEC 60738-1 IEC 60738-1 IEC 60738-1 Test conditions Room temperature, ISmax; Vmax Number of cycles: 10 Storage at Vmax /Top,max (Vmax) Test duration: 1000 h Temperature of air: 40 C Relative humidity of air: 93% Duration: 56 days Test according to IEC 60068-2-78 T1 = Top,min (0 V), T2 = Top,max (0 V) Number of cycles: 5 Test duration: 30 min Test according to IEC 60068-2-14, Test Na Frequency range: 10 to 55 Hz Displacement amplitude: 0.75 mm Test duration: 3 x 2 h Test according to IEC 60068-2-6, Test Fc Acceleration: 390 m/s2 Pulse duration: 6 ms; 6 x 4000 pulses Dry heat: T = Top,max (0 V) Test duration: 16 h Damp heat first cycle Cold: T = Top,min (0 V) Test duration: 2 h Damp heat 5 cycles Tests performed according to IEC 60068-2-30 R25/R25 < 20% < 25% < 10%
Rapid change of temperature
IEC 60738-1
< 10%
Vibration
IEC 60738-1
< 5%
Shock Climatic sequence
IEC 60738-1 IEC 60738-1
< 5% < 10%
Please read Cautions and warnings and Important notes at the end of this document.
Page 7 of 13
Overcurrent protection for telecom Telecom pair protector (TPP), SMD
ITU performance overview and test conditions Test no. Power induction Power contact Lightning surge 1 2 3 4 5 ITU K20 Basic test level A B D F H Enhanced test level A C E G H ITU K21 Basic test level A B D G H Enhanced test level A C E G I ITU K45 Basic test level A B D G H Enhanced test level A C E G H
Power induction
A B C D E F G H I
Power contact
600 V AC, R = 600 , t = 0.2 s, criteria A 600 V AC, R = 600 , t = 1.0 s, with GDT, criteria A 1500 V AC, R = 200 , t = 2.0 s, with GDT, criteria A 230 V AC, t = 15 min, R = 10 ... 1000 , criteria B 230 V AC, t = 15 min, R = 10, 20, 40, 80, 1000 , criteria B, R = 160, 300, 600 , criteria A Uc(max) = 1.0 kV, R = 25 , t = 10/700 s, without GDT, criteria A Uc(max) = 1.5 kV, R = 25 , t = 10/700 s, without GDT, criteria A Uc(max) = 4.0 kV, R = 25 , t = 10/700 s, with GDT, criteria A Uc(max) = 6.0 kV, R = 25 , t = 10/700 s, with GDT, criteria A
Lightning surge
Criteria A: no damage, function must be fulfilled. Criteria B: no fire hazard. Electrical requirements according to GR1089 standard for AC power contact AC voltage: 120 V, 50 Hz, short circuit current 25 A, time 15 min, criteria A.
Please read Cautions and warnings and Important notes at the end of this document.
Page 8 of 13
Overcurrent protection for telecom Telecom pair protector (TPP), SMD
Cautions and warnings General EPCOS thermistors are designed for specific applications and should not be used for purposes not identified in our specifications, application notes and data books unless otherwise agreed with EPCOS during the design-in-phase. Ensure suitability of thermistor through reliability testing during the design-in phase. The thermistors should be evaluated taking into consideration worst-case conditions. Storage Store thermistors only in original packaging. Do not open the package before storage. Storage conditions in original packaging: storage temperature 25 C ... +45 C, relative humidity 75% annual mean, maximum 95%, dew precipitation is inadmissible. Avoid contamination of thermistors surface during storage, handling and processing. Avoid storage of thermistor in harmful environment with effect on function on long-term operation (examples given under operation precautions). Use thermistor within the following period after delivery: Through-hole devices (housed and leaded PTCs): 24 months Motor protection sensors, glass-encapsulated sensors and probe assemblies: 24 months Telecom pair and quattro protectors (TPP, TQP): 24 months Leadless PTC thermistors for pressure contacting: 12 months Leadless PTC thermistors for soldering: 6 months SMDs in EIA sizes 3225 and 4032, and for PTCs with metal tags: 24 months SMDs in EIA sizes 0402, 0603, 0805 and 1210: 12 months Handling PTCs must not be dropped. Chip-offs must not be caused during handling of PTCs. Components must not be touched with bare hands. Gloves are recommended. Avoid contamination of thermistor surface during handling. Soldering (where applicable) Use rosin-type flux or non-activated flux. Insufficient preheating may cause ceramic cracks. Rapid cooling by dipping in solvent is not recommended. Complete removal of flux is recommended. Standard PTC heaters are not suitable for soldering.
Please read Cautions and warnings and Important notes at the end of this document.
Page 9 of 13
Overcurrent protection for telecom Telecom pair protector (TPP), SMD
Mounting Electrode must not be scratched before/during/after the mounting process. Contacts and housing used for assembly with thermistor have to be clean before mounting. Especially grease or oil must be removed. When PTC thermistors are encapsulated with sealing material, the precautions given in chapter "Mounting instructions", "Sealing and potting" must be observed. When the thermistor is mounted, there must not be any foreign body between the electrode of the thermistor and the clamping contact. The minimum force of the clamping contacts pressing against the PTC must be 10 N. During operation, the thermistor's surface temperature can be very high. Ensure that adjacent components are placed at a sufficient distance from the thermistor to allow for proper cooling at the thermistors. Ensure that adjacent materials are designed for operation at temperatures comparable to the surface temperature of thermistor. Be sure that surrounding parts and materials can withstand this temperature. Avoid contamination of thermistor surface during processing. Operation Use thermistors only within the specified temperature operating range. Use thermistors only within the specified voltage and current ranges. Environmental conditions must not harm the thermistors. Use thermistors only in normal atmospheric conditions. Avoid use in deoxidizing gases (chlorine gas, hydrogen sulfide gas, ammonia gas, sulfuric acid gas etc), corrosive agents, humid or salty conditions. Contact with any liquids and solvents should be prevented. Be sure to provide an appropriate fail-safe function to prevent secondary product damage caused by abnormal function (e.g. use VDR for limitation of overvoltage condition).
Please read Cautions and warnings and Important notes at the end of this document.
Page 10 of 13
Overcurrent protection for telecom Telecom pair protector (TPP), SMD
Symbols and terms A Cth f I Imax IR IPTC Ir Ir,oil Ir,air IRMS IS ISmax LCT N Nc Nf P P25 Pel Pdiss Rmin RR RR RP RPTC Rref RS R25 R25,match R25 T t TA ta TC Area Heat capacity Frequency Current Maximum current Rated current PTC current Residual currrent Residual currrent in oil (for level sensors) Residual currrent in air (for level sensors) Root-mean-square value of current Switching current Maximum switching current Lower category temperature Number (integer) Operating cycles at Vmax, charging of capacitor Switching cycles at Vmax, failure mode Power Maximum power at 25 C Electrical power Dissipation power Minimum resistance Rated resistance Tolerance of RR Parallel resistance PTC resistance Reference resistance Series resistance Resistance at 25 C Resistance matching per reel/ packing unit at 25 C Tolerance of R25 Temperature Time Ambient temperature Thermal threshold time Ferroelectric Curie temperature
Please read Cautions and warnings and Important notes at the end of this document.
Page 11 of 13
Overcurrent protection for telecom Telecom pair protector (TPP), SMD
tE TR Tsense Top TPTC tR Tref TRmin tS Tsurf UCT V or Vel VRMS VBD Vins Vlink,max Vmax Vmax,dyn Vmeas Vmeas,max VR VPTC th th
Settling time (for level sensors) Rated temperature Sensing temperature Operating temperature PTC temperature Response time Reference temperature Temperature at minimum resistance Switching time Surface temperature Upper category temperature Voltage (with subscript only for distinction from volume) Root-mean-square value of voltage Breakdown voltage Insulation test voltage Maximum link voltage Maximum operating voltage Maximum dynamic (short-time) operating voltage Measuring voltage Maximum measuring voltage Rated voltage Voltage drop across a PTC thermistor Temperature coefficient Tolerance, change Dissipation factor Thermal cooling time constant Failure rate Lead spacing (in mm)
Abbreviations / Notes Surface-mount devices * To be replaced by a number in ordering codes, type designations etc. + To be replaced by a letter All dimensions are given in mm. The commas used in numerical values denote decimal points.
Please read Cautions and warnings and Important notes at the end of this document.
Page 12 of 13
Important notes
The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap, DSSP, MiniBlue, MiniCell, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
Page 13 of 13


▲Up To Search▲   

 
Price & Availability of B59635T1120A062

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X